Description
Technical Specifications
Plasma Deflector 220955 Details:
- Part Number: 220955
- Classification: Plasma Arc Deflector / Flow Control Component
- Primary Technology: Plasma arc direction control and optimization
- Compatible Systems: PowerMax 65, 85, 105 with FineCut and standard consumables
- Internal Function: Torch component protection and plasma flow management
- Material Engineering: High-temperature resistant materials for extreme plasma conditions
- Performance Enhancement: Cut quality improvement through arc optimization
- Service Characteristics: Extended protection for critical internal components
Arc Control Technology Features:
- Plasma Flow Direction: Precise control of plasma arc direction for optimal cutting
- Internal Component Protection: Advanced heat shielding for expensive torch parts
- Cut Quality Enhancement: Reduced spatter and improved cutting consistency
- Performance Optimization: Fine-tuned plasma flow for superior results
Understanding Plasma Deflector Technology
What Makes Deflectors Essential: Plasma deflectors work inside the torch to control and optimize plasma flow while protecting critical internal components from the extreme heat and spatter generated during cutting. The 220955 represents advanced arc control technology that most users never see but always benefit from.
Arc Control Benefits:
- Optimized Plasma Flow: Precise direction control for improved cutting efficiency
- Internal Component Protection: Heat shielding extends expensive part life significantly
- Cut Quality Enhancement: Reduced spatter and dross for cleaner, more precise cuts
- Performance Consistency: Stable arc characteristics for repeatable results
- System Reliability: Protection of critical components reduces unexpected failures
- Cost Efficiency: Extended component life reduces overall operating costs
When Arc Control Technology Matters Most: In demanding cutting applications where cut quality, component life, and operational reliability directly affect productivity and costs.
Internal Protection Performance
What Arc Control Technology Delivers:
- Precise Plasma Management: Controlled arc direction for optimal cutting performance
- Component Life Extension: Internal protection significantly extends torch component life
- Quality Enhancement: Improved cut consistency through better arc control
- Reduced Maintenance: Less frequent component replacement due to thermal damage
- Operational Reliability: Consistent performance through proper internal protection
Performance in Demanding Applications:
- High-Volume Cutting: Continuous protection for production environments
- Precision Applications: Arc stability for demanding cut quality requirements
- Industrial Operations: Reliable protection for critical production processes
- Professional Services: Consistent performance for customer-facing operations
Professional Results Depend On:
- Proper Arc Control: Using correct deflector for optimal plasma flow management
- Internal Protection: Adequate thermal shielding for component longevity
- System Integration: Complete torch assembly optimization for best results
- Regular Maintenance: Timely deflector replacement for continued protection
System Compatibility & Internal Optimization
PowerMax Internal System Compatibility:
- PowerMax 65: Essential arc control for mid-range cutting applications
- PowerMax 85: Critical internal protection for high-performance cutting
- PowerMax 105: Required component protection for maximum power applications
Complete Internal Protection System:
- Deflector 220955 – This arc control deflector
- Electrode 220842 – Protected internal electrode
- Retaining Cap 220854 – System stability component
- Compatible shields – External protection for complete system optimization
Critical Internal Requirements: Optimal cutting performance requires proper internal arc control and component protection. The 220955 deflector is essential for managing plasma flow and protecting expensive internal components.
Installation & Internal System Maintenance
Professional Installation Procedure:
- Verify PowerMax system compatibility and torch configuration
- Power down plasma system completely and allow cooling
- Disassemble torch head following manufacturer procedures
- Remove old deflector and inspect internal components for wear
- Install 220955 deflector ensuring proper alignment for arc control
- Verify secure fit and proper positioning for optimal plasma flow
- Reassemble torch components following precise sequence
- Test system operation and arc performance
Internal System Maintenance:
- Component Inspection: Regular assessment of deflector condition and performance
- Thermal Monitoring: Watch for signs of excessive heat damage or wear
- Performance Tracking: Monitor cut quality and arc stability indicators
- Replacement Timing: Replace before internal protection compromises
- System Integration: Maintain complete torch assembly for optimal results
Maximizing Internal Protection:
- Complete System Approach: Use quality components throughout torch assembly
- Proper Installation: Ensure correct deflector positioning for optimal arc control
- Regular Assessment: Monitor internal component condition regularly
- Professional Maintenance: Follow manufacturer guidelines for internal system care
Arc Control Applications
Production Environment Protection: Production facilities rely on the 220955 for consistent arc control and internal component protection that supports demanding manufacturing schedules.
High-Volume Cutting Operations: Continuous cutting operations depend on reliable internal protection to maintain performance and minimize unexpected component failures.
Precision Cutting Applications: Applications requiring consistent cut quality benefit from the arc control technology that ensures stable, optimized plasma flow.
Professional Cutting Services: Service providers depend on internal component protection to maintain reliable equipment performance and minimize costly downtime.
Cost-Benefit for Internal Protection
Internal Protection Investment: Deflectors represent essential investment in equipment protection that delivers significant returns through extended component life and improved performance.
Professional Value Proposition:
- Component Life Extension: Internal protection significantly extends expensive part life
- Performance Optimization: Arc control technology improves cutting results
- Operational Reliability: Consistent internal protection reduces unexpected failures
- Cost Control: Extended component life reduces overall operating expenses
When Internal Protection Investment Pays Off:
- High-volume operations: Where component replacement costs affect profitability
- Production environments: When equipment reliability affects output
- Professional services: Where downtime costs impact business operations
- Quality-critical applications: When consistent performance is essential
Quality & Internal Protection Standards
What We Promise:
- Advanced arc control technology for PowerMax internal optimization
- Internal component protection for extended service life
- Compatible with FineCut and standard consumable systems
- Replacement if defective (though deflectors are precision-engineered)
Internal Protection Reality:
- Installation critical: Proper fitting essential for optimal arc control and protection
- System integration required: Best results need complete torch assembly optimization
- Regular replacement necessary: Timely replacement maintains protection effectiveness
- Professional results: Performance depends on proper internal system maintenance
Professional Support:
- Installation guidance: Proper procedures for optimal internal protection
- System optimization: Complete torch assembly setup for maximum benefits
- Performance monitoring: Guidelines for assessing internal protection effectiveness
- Technical expertise: Professional support for demanding applications
Ordering Information
For Professional Operations:
- Production Facilities: Volume pricing for manufacturing environments
- High-Volume Cutting: Commercial rates for continuous operations
- Professional Services: Competitive pricing for service providers
- Industrial Applications: Support for demanding cutting environments
Professional Availability:
- Production Priority: Maintained inventory for critical internal components
- Quality Assurance: Arc control performance guaranteed
- Technical Support: Expert guidance for internal system optimization
Professional Pricing: Arc control technology represents advanced internal protection engineering for demanding applications. The investment delivers measurable returns through component protection and performance optimization.
| PMX65A/85A/105A | 220842 | Electrode | PMX125A | 220971 | Electrode |
| 220941 | Nozzle | 220975 | Nozzle | ||
| 220816 | Nozzle | 420158 | Nozzle | ||
| 220819 | Nozzle | 420169 | Nozzle | ||
| 220990 | Nozzle | 420168 | Shield | ||
| 220817 | Shield | 420156 | Shield | ||
| 220993 | Shield | 220976 | Shield | ||
| 220857 | Vortex Ring | 420000 | Shield | ||
| 220994 | Vortex Ring | 220997 | Vortex Ring | ||
| 220854 | Fixed Cover | 220977 | Fixed Cover | ||
| 220953 | Fixed Cover | 428144 | / | ||
| 220818 | Shield | 428145 | / | ||
| 220992 | Shield | 428548 | / | ||
| 220948 | Shield | 428147 | / | ||
| 220955 | Shield | PMX1250A | 120926 | Electrode | |
| 220931 | Shield | 120927 | Nozzle | ||
| 220930 | Nozzle | 120931 | Nozzle | ||
| 220947 | Vortex Ring | 120932 | Nozzle | ||
| 220797 | Nozzle | 120980 | Nozzle | ||
| 220991 | Nozzle | 220007 | Nozzle | ||
| 220798 | Nozzle | 220006 | Nozzle | ||
| 228716 | Noumenon | 120929 | Shield | ||
| 228735 | / | 120930 | Shield | ||
| 228737 | / | 120925 | Vortex Ring | ||
| / | / | / | 120928 | Fixed Cover | |
| MAX200 HT2000 | 220021 | Electrode | GPR130 | 220181 | Electrode |
| 20608 | Nozzle | 220182 | Nozzle | ||
| 20605 | Nozzle | 220183 | Shield | ||
| 20689 | Nozzle | 220187 | Electrode | ||
| 20690 | Nozzle | 220188 | Nozzle | ||
| 20424 | Shield | 220189 | Shield | ||
| 20448 | Shield | 220179 | Vortex Ring | ||
| 20607 | Vortex Ring | 220176 | Fixed Cover | ||
| 120837 | Fixed Cover | 220756 | Fixed Cover | ||
| 20423 | Fixed Cover | 220173 | Fixed Cover | ||
| 20963 | Water Pipe | 220747 | Fixed Cover | ||
| HPR260 | 220352 | Electrode | HSD130 | 220487 | Electrode |
| 220354 | Nozzle | 220525 | Nozzle | ||
| 220353 | Vortex Ring | 220530 | Nozzle | ||
| 220761 | Shield | 220489 | Nozzle | ||
| 220356 | Shield | 220492 | Nozzle | ||
| 220435 | Electrode | 220532 | Shield | ||
| 220439 | Nozzle | 220491 | Shield | ||
| 220764 | Shield | 220536 | Shield | ||
| 220436 | Vortex Ring | 220488 | Vortex Ring | ||
| 220760 | Fixed Cover | 220890 | Nozzle | ||
| 220637 | Fixed Cover | 220892 | Nozzle | ||
| 220571 | Water Pipe | 220891 | Nozzle | ||
| 220340 | Water Pipe | 220521 | Water Pipe | ||
| MAXPRO200 | 220528 | Electrode | 220529 | Vortex Ring | |
| 220578 | Fixed Cover | IF YOU NEED OTHER MODELS YOU CAN CONSUL CUSTOMER SERVICE | |||
| 220937 | Electrode | ||||
| 420044 | Nozzle | ||||
| 420045 | Shield | ||||
| 220488 | Vortex Ring | ||||
| 220936 | Fixed Cover | ||||
| 220935 | Fixed Cover | ||||
| 220831 | Nozzle | ||||
| 220832 | Shield | ||||
Engineering usage examples:
Frequently Asked Questions
Q: What’s the difference between a deflector and a shield?
A: Deflectors work inside the torch for arc control and internal protection, while shields provide external protection. Both are essential for complete system protection.
Q: How often should I replace the deflector?
A: Replace when you notice reduced cut quality, increased spatter, or visible wear during torch maintenance. Typically every 150-300 cutting hours depending on usage.
Q: Can I cut without a deflector?
A: No, deflectors are essential for arc control and internal component protection. Operating without proper deflection will damage expensive internal components.
Q: Will this improve my cut quality?
A: Yes, proper arc control from a functioning deflector improves cut consistency, reduces spatter, and enhances overall cutting performance.
Q: Is this compatible with all PowerMax models?
A: The 220955 is designed for PowerMax 65, 85, and 105 systems. Verify compatibility with your specific model before ordering.
Q: How do I know if my deflector needs replacement?
A: Signs include increased spatter, reduced cut quality, irregular arc behavior, or visible wear during torch inspection.
Arc Control Applications Guide
Internal Component Protection:
- Production environments: Continuous internal protection for manufacturing operations
- High-volume cutting: Reliable component protection for demanding schedules
- Professional services: Equipment protection for business-critical operations
Performance Optimization:
- Quality-critical cutting: Arc control for consistent, high-quality results
- Precision applications: Stable plasma flow for demanding specifications
- Professional operations: Optimized performance for competitive advantages
System Reliability:
- Industrial operations: Internal protection for critical production equipment
- Service providers: Equipment reliability for customer satisfaction
- Cost-conscious operations: Component protection for controlled operating expenses
Storage & Internal Component Handling
Professional Storage:
- Store in controlled environment to maintain precision characteristics
- Protect from contamination that could affect internal performance
- Maintain professional inventory for critical component availability
- Handle as precision internal component
Quality Control:
- Pre-installation inspection: Verify condition for optimal arc control
- Professional installation: Follow proper procedures for internal components
- Performance monitoring: Track arc control effectiveness and cut quality
- System integration: Ensure complete torch assembly optimization
Professional Best Practices:
- Complete system approach: Maintain all internal components for optimal protection
- Regular assessment: Monitor internal component condition consistently
- Professional procedures: Follow manufacturer guidelines for internal system care
- Performance optimization: Leverage arc control technology for competitive advantages
Reviews From Real Customers
Reviews
There are no reviews yet.